VIEW CATALOG


PRODUCT SEARCH


QUICK QUESTIONS

Name:
Email(Optional):
State/Region:
Phone:
Product Description
Verification Code:
This Is CAPTCHA Image

To verify content, please enter in the characters in the image above (Case sensitive)

WEIZEL FACTS

Weizel presently serves 1,755 correctional and prison facilities in North America 2006 Incarceration Facts

U.S.A: 2.2 Million inmates in approx. 7,000 facilities.

Canada: 38,000 inmates in approx. 450 facilities

Weizel presently serves 2,454 hospitals in North America


TOOLS & SERVICES

Currency Converter
Form Center
How-To: Request Quote
Pricing Policy



 

51E Series

51E Lock.gif (54097 bytes)

OPERATIONS:
Standard (1): When connected to a momentary-contact switch, the latchbolt retracts when the solenoid is energized. Once retracted, the latchbolt is held mechanically retracted until the door is opened. The latchbolt extends when the door is open.   
Standard (1a): When connected to a maintained-contact switch, the latchbolt retracts when the solenoid is energized. Once retracted, it is held electrically retracted for an extended period of time. The latchbolt extends only when the solenoid is de-energized.
No-notch (2): Latchbolt extends when the switch is selected to lock (no-notch feature see optional features) 

STANDARD COMPLIANCES:
All 51E Series models are UL1034 listed as Burglary-Resistant Mechanisms, and UL10B listed as Fire Door Accessories to a three-hour rating.

 STANDARD FEATURES:
  • Solenoid voltage - 120VAC
  • Two piece plug connector - Simplifies wiring.
  • Instant solenoid operation - Dependable, continuous-duty solenoid.
  • Automatic deadlocking - When the latchbolt is extended, it automatically deadlocks on closure.
  • Full ¾" bolt throw - Projects ¼" when retracted.
  • Mechanical unlocking by key - During power failure, or any time the lock unlocks by use of prison paracentric key. Latchbolt remains retracted until relocked by key.
  • Indication switch - A lock status indication switch which monitors the extension of the latch bolt and the deadlocked condition is included.
  • Rugged construction - Case and cover are 7 gauge steel.
  • Choice of five or six tumbler models.
  • Solid steel latchbolt - Latchbolt is galvanized steel, concealed pins resist sawing.
  • Deadlock actuator - Roller type, galvanized steel, adjustable for variations in door-to-jamb clearance.
  • Finish - Standard is USP

 

OPTIONAL FEATURES:

  • Solenoid voltage - 220VAC
  • Bolt projection - Standard ¼" when retracted. ¾" throw. Consult factory for other projections.
  • No-notch feature - The holdback lever has no notch to hold the latchbolt mechanically retracted. The latchbolt extends in the locked position regardless of the position of the door.
  • Interlocking - Accomplished through the control console.
  • Finish - Galvanized

51M Series

50m.gif (8282 bytes)

STANDARD COMPLIANCE:
51M Series Deadlatches are UL1034 listed as Burglary-Resistant Mechanisms, and UL10B listed (except 51MC models) as Fire Door Accessories to a three-hour rating.

STANDARD FEATURES:
  • Motor voltage - 120VAC
  • Two piece plug connector - Simplifies wiring.
  • Quiet operation - Unlocks by smooth motor action.
  • Automatic deadlocking - All models automatically deadlock on closure.
  • Rugged construction - 7 gauge steel for durability.
  • Indication switch - A lock status indication switch which monitors the extension of the latch bolt and the dead locked condition is included.
  • Five or six tumbler models available
  • Mechanical unlocking by key - In the event of power failure, or at any time, 51M Series deadlatches may be unlocked by prison paracentric key, latchbolt remains retracted until relocked by key.
  • Solid steel latchbolt - Galvanized, with two hardened steel pins to resist sawing.
  • Deadlocking actuator - Roller type, galvanized steel, adjustable for variations indoor to jamb clearance.
  • Full ¾" bolt throw - Projects ¼" when retracted.
  • Finish - Standard USP, primed

OPTIONAL FEATURES:
  • Motor voltage - 220VAC, 24DC
  • Bolt projection - Standard ¼" when retracted. ¾" bolt throw. Consult factory for other projections.
  • Continuous duty function - Using a two-position, maintained contact switch, and a two position cam on the motor, the latchbolt may be held retracted for extended periods. The latchbolt extends only when the door is open and the motor is energized a second time. The latchbolt deadlocks when extended and the door is closed.
  • No-notch feature - The holdback lever has no notch to hold the latchbolt mechanically retracted. This feature may be used with Continuous Duty feature, and operates in the same manner as above, except that the latchbolt extends when the motor is energized a second time regardless of the position of the door.
  • Interlock switch - An interlock switch is added which prevents electrical unlocking of other doors in a system when one is unlocked.
  • Finish - Galvanized

50HBM Series
 

OPERATION:
All 50HBM locks are operated by electric motor. The choice of three motor operations provides a variety of functions:

FULL-ROTATION MOTOR
(50HBM)

With latchback (1), 01:
Unlocks when the motor is energized by a momentary contact switch. Once unlocked, the hookbolt is held mechanically in the raised position until the door is opened. It then returns to normal, lowered position.

TWO-POSITION MOTOR
(50HBMC)

Without latchback (2), 04:
Same as above, except that the hookbolt is raised and lowered as the motor runs. A door starter should be installed in the track housing to push the door open when the motor reaches the unlocking point.

TESTING:
50HBM locks have been tested in Folger Adam Security Inc. facilities for over one million operations

 

STANDARD FEATURES:

  • Motor voltage - 120VAC
  • External mounting - Locks install without cover plate removal. External slotted mounting holes simplify installation, and allow for variations in door gap by permitting lateral movement.
  • Two-piece plug connector - Simplifies wiring at time of installation, and allows pre-wiring at the lock pocket.
  • Superior durability - Working parts are stainless steel and designed for maximum strength, and corrosion resistance.
  • Hardened hookbolt and deadlock actuator - Galvanized for corrosion resistance.
  • Motor operation - A choice of three operations is available.
  • Choice of five or six lever tumbler models.
  • Mechanical unlocking by key - Once unlocked by key, the hookbolt remains in that position until relocked by key (Models without latchback feature). Key is removable in the unlocked position.
  • Indication switch - The indication switch monitors the deadlock lever a for indicating a deadlocked hookbolt.

OPTIONAL FEATURES:

  • Motor voltage - 24DC
  • Lock bolt keepers - Select 50H-4DB with dust box

SPECIFICATION:

  • Case - 7 and 10 gauge steel
  • Cover - 10 gauge HRS
  • Hookbolt - .5 inch steel, case hardened and galvanized
  • Deadlock actuator - .5 inch square CRS, hardened and galvanized
  • Deadlock and Operator levers - Stainless steel
  • Springs - Stainless steel
  • Motor - Synchronous-type gearmotor with break

ELECTRICAL CHARACTERISTICS:

Motor (AC):      Synchronous-type gearmotor with break
Ratings:    120VAC, 60HZ, 1.3 amps at full load
Motor (DC): Permanent magnet gearmotor
Ratings:    24DC, 2.2 amps at full load
Ind Switch:      SPDT, UL Listed
Deadlock:   15 amps 125 or 250 VAC
Auxiliary:    10 amps 125 or 250 VAC


120E, 120RUP, 120ED, 120EDR Locks

OPERATIONS:
Standard (1):
Series 120E locks unlock when the solenoid is energized by a momentary-contact switch. Once unlocked, the latchbolt is held mechanically retracted until the door is opened. It then extends automatically. Two additional variations on the operation are offered in 120E Series locks.

Without latchback (1a),  04,05:
Once unlocked, the latchbolt is held retracted as long as the solenoid is energized. A maintained-contact switch may be used to keep the latchbolt retracted for an extended period of time.

Electric Holdback (1b), 07:
Once unlocked, the latchbolt is held electrically retracted until the door is opened. It then extends automatically. This operation requires an additional control wire, and may be cancelled by adding an additional control switch.

Knob release(2):
120E Deadlatches may be specified with knob release on one side, where the knob is always active.
Knob may be mounted on the case side, or the cover side.

Key holdback (3):
When unlocked by key, the deadlatch remains retracted until relocked by turning the key in the opposite direction. Available one side only.
Note: Key cylinders for locks with key holdback feature must be installed at the factory.

TESTING:
120E Series Deadlatches and Maxi-Mogul Key Cylinders have been tested to 1,000,000 operations.

STANDARD COMPLIANCE:
All series120E locks are UL1034: Burglary-Resistant Mechanisms, and some are UL10B listed as Fire Door Accessories to a three-hour rating. Key holdback models are not UL10B listed.
Maxi-Mogul Key Cylinders meet UL437 requirements.


STANDARD FEATURES:

Solenoid voltage-120 VAC
Superior durability- Working parts of stainless steel afford greater strength, and
corrosions resistance.
Standard lock size- All models use the same size case, cover and mounting holes for simplified installation and frame preparation.
External two-piece plug connector- All models install without cover removal. Simple
plug-in connection to field wiring.
External mounting holes- Ease installation, and the need for cover removal.
Standard lock- Mounts behind frame and does not require a faceplate.
1" throw latchbolt- Offers greater security. Each has inserts to resist sawing. When
latchbolt is engaged in strike, bevel is concealed to prevent picking.
Mechanical unlocking by key- Specify Folger Adam Mogul cylinders, Maxi-Mogul
high security cylinders, or builders hardware cylinders to match other locks.
Investment cast stainless steel strike- Furnished with four Torx tamper-resistant screws.
Continuous-duty solenoid- For instant action.
Finish- USP primed for paint.


OPTIONAL FEATURES
Faceplate- For applications requiring a finished faceplate, specify US4, US10, US10B,
US32, or US32D
Indication/auxiliary switches- An indication switch monitors the deadlock lever indicating a deadlocked latchbolt. The auxiliary switch monitors the latchbolt for extended or retracted position.
Local electric key (LEK) (LEK)- A unique function which uses two types of keys. One key turns in one direction only, and operates the lock electrically. The supervisory key turns in both directions to operate the lock electrically or mechanically. The electric operation may be cancelled from a central console or control point at any time via a three-position switch. For applications where inmates carry their own keys, but supervision is necessary. The Maxi-Mogul Key Cylinder is uniquely suited for this high frequency operation, shown by cycle test of 1,000,000 operations.
Galvanized case and cover- For exterior applications.
Key Cylinder Extension- When the lock is keyed on the stop side of the jamb, an extension eliminates the need for a special, recessed frame pocket.
Optional solenoid voltage- 230 VAC, 60Hz.


SPECIFICATIONS:
Case and cover:           10 gauge steel
Latchbolt:                       Investment cast stainless steel with hardened inserts, 1" throw.
Deadlock lever:              Stainless steel, adjustable for door gap variations.
Bolt opening does not allow access to mechanism.
Roller Bolt:                      Investment cast stainless steel with stainless steel roller.
Operating lever:             Stainless steel to operate with solenoid.
Strike:                             Investment cast stainless steel, attached with screws in two directions.
Solenoid:                        120 VAC continuous duty with stainless steel guides, 230VAC optional.
Springs:                         Stainless Steel.

ELECTRICAL CHARACTERISTICS:
       
Solenoid Voltages:  120 VAC, 13 amps inrush - .75 amps seated
                                      230 VAC, 6.6 amps inrush - .38 amps seated
        Switches:                SPDT, UL Listed
                                      15 amps @ 125 or 250 VAC


120M, 120MC, 120MI Locks
OPERATION:
Standard (1):
Series 120M locks unlock when the motor is energized by a momentary-contact switch.
Once unlocked, the latchbolt is held mechanically retracted until the door is opened. It then extends
automatically.

Knob release(2):
120M Deadlatches may be specified with knob release on one side, where the knob is always active.
Knob may be mounted on the case side, or the cover side.

Key holdback (3):
When unlocked by key, the deadlatch remains retracted until relocked by turning the key in the
opposite direction. Available one side only.
Note:Key cylinders for locks with key holdback feature must be installed at the factory.


TESTING:

120M Series Deadlatches and Maxi-Mogul Key Cylinders have been tested to 1,000,000 operations.

STANDARD COMPLIANCE:
All series120M locks are UL1034: Burglary-Resistant Mechanisms, and some are UL10B listed as
Fire Door Accesories to a three-hour rating. Key holdback models are not UL10B listed.
Maxi-Mogul Key Cylinders meet UL437 requirements.


STANDARD FEATURES:

    Motor voltage
-120 VAC
    Superior durablility- Working parts of stainless steel afford greater strength, and
corrosions resistance.
    Standard lock size- All models use the same size case, cover and mounting holes for simplified installation and frame preparation.
    External two-piece plug connector- All models install without cover removal. Simple plug-in connection to field wiring.
    External mounting holes- Ease installation, and elimanate the need for cover removal.
    Standard lock- Mounts behind frame and does not require a faceplate.
    1" throw latchbolt- Offers greater security. Each has inserts to resist sawing. When latchbolt is engaged in strike, bevel is concealed to prevent picking.
    Mechanical unlocking by key- Specify Folger Adam Mogul cylinders, Maxi-Mogul high security cylinders, or builders hardware cylinders to match other locks.
    Investment cast stainless steel strike- Furnished with four Torx tamper-resistant screws.
    Fractional HP Motor-Permanently lubricated for smooth quiet operation with thermal overload protection and a brake for accurate locking position.
    Finish- USP primed for paint.


OPTIONAL FEATURES

Faceplate
- For applications requiring a finished faceplate, specify US4, US10, US10B,
US32, or US32D
Indication/auxiliary switches- An indication switch monitors the deadlock lever indicating
a deadlocked latchbolt. The auxiliary switch monitors the latchbolt for extended or retracted postion.
Local electric key (LEK)- A unique function which uses two types of keys. One key turns in one direction only, and operates the lock electrically. The supervisory key turns in both directions to operate the lock electrically or mechanically. The electric operation may be cancelled from a central console or control point at any time via a three-position switch. For applications where inmates carry their own keys, but supervision is necessary. The Maxi-Mogul Key Cylinder is uniquely suited for this high frequency operation, shown by cylcle test of 1,000,000 operations.
Galvanized case and cover- For exterior applications.
Key Cylinder Extension- When the lock is keyed on the stop side of the jamb, an extension eliminates the need for a special, recessed frame pocket.
Optional solenoid voltage- 24 VAC or 24 VDC.


SPECIFICATIONS:
Case and cover - 10 gauge steel
Latchbolt- Investment cast stainless steel with hardened inserts, 1" throw.
Deadlock lever- Stainless steel, adjustable for door gap variations.
Bolt opening does not allow access to mechanism.
Roller Bolt- Investment cast stainless steel with stainless steel roller.
Operating lever- Stainless steel to operate with solenoid.
Strike- Investment cast stainless steel, attached with screws in two directions.
        Motor- 120 VAC continuous duty, 24 VAC or 24 VDC optional, synchronous-type gearmotor.
        Springs- Stainless Steel.

ELECTRICAL CHARACTERISTICS:
       
AC Motors:             Synchronous-type gearmotor with break.
        Ratings:                 120 VAC, 60 Hz, 1.3 amps at full load.
                                      24 VAC, 60 Hz, 6.1 amps at full load.
        DC Motors:             Permanent-magnet gearmotor.
        Ratings:                 24 VDC, 2.2 amps at full load.
        Switches:              SPDT, UL Listed
                                    15 amps @ 125 or 250 VAC

Model Number

Operation

Latchback

Indication Switches

LEK Available
YES/NO

With

Without

Deadlatch

Aux

120M-1-01

Standard(1)

X

 

X

 

Yes

120M-1-02

Standard(1)

X

 

X

X

Yes

120M-2-01

Knob Rel. (2)

X

 

X

 

Yes

120M-2-02

Knob Rel. (2)

X

 

X

X

Yes

120M-3-01

Key Holdback(3)

X

 

X

 

No

120M-3-02

Key Holdback(3)

X

 

X

X

No

Model Number Operation Latchback Relock
Switch
Indication Switches LEK Available
YES/NO
With Without Deadlatch Aux
120MC-1-01 Standard(1)

X

    X   Yes
120MC-1-02 Standard(1) X     X X Yes
120MC-1-04 Standard(1a)   X   X   Yes
120MC-1-05 Standard(1a)   X   X X Yes
120MC-1-09 Standard(1b)   X X X   Yes
120MC-2-01 Knob Rel. (2) X      X   Yes
120MC-2-02 Knob Rel. (2) X      X X Yes
120MC-2-04 Knob Rel. (2)   X   X   Yes
120MC-2-05 Knob Rel. (2)   X   X X Yes
120MC-2-09 Knob Rel. (2)   X X X   Yes
120MC-3-01 Key Holdback(3) X     X   No
120MC-3-02 Key Holdback(3) X     X X No
120MC-3-04 Key Holdback(3)    X    X    No
120MC-3-05 Key Holdback(3)    X    X X No
120MC-3-09 Key Holdback(3)    X X X    No

 

125-2 & 125-3 Series  

125.gif (22101 bytes)

STANDARD FEATURES:
  • Folger Adam Mogul or Maxi-Mogul Key Cylinder - Specially designed, at almost twice the size of an ordinary builders hardware key cylinder - with all of its working parts in the same, larger proportin - extra durable and pick resistant.
  • Deadlocks automatically - When door is closed.
  • Fits doors 1-3/4" thick - Or more. Specify door thickness when ordering.
  • Solenoid-actuated knob lock-out - 24DC, tubular, continuous-duty solenoid.
  • Armored front - Adjustable, from flat to 1/8" in 2" bevel. Consists of a stainless steel backplate and brass faceplate.
  • Case and cover - Investment cast bronze alloy. Case has closed front and latch-bearing surfaces for extra strength.
  • Corrosion-resistant working parts
  • Latchbolt and deadlock actuator - Investment cast stainless steel.
  • Knobs and roses - Solid brass. Knobs are attached to spindle by exposed set screws on one side, and, depending on function, by either concealed set screws or a concealed cross pin on the other side.
  • Spindle size - 0.343" square steel, on the diamond.
  • Latchbolt size - 1-3/8" high x 5/8" thick
  • Latchbolt throw - ¾", flush when retracted.
  • Torx tamper resistant screws - For attaching faceplate, strike, and knob rose.
  • Strike - 0.090" thick stainless steel, with mounting screws.
  • Field reversible - Latchbotl and deadlock actuator can be rotated to reverse the handing of the lock.
  • Finish - Trim US4, satin brass, lacquered

OPTIONAL FEATURES:
  • Finish - Faceplate 32D, Key cylinder, knobs and roses: 26D
  • Preparation for builders hardware key cylinder - A specially designed adaptor is added to the lock for accepting a builders hardware, mortise key cylinder. Builders hardware key cylinders may be supplied by either the factory or by customer.
    NOTE: Customer supplied key cylinders must:
    a) be 1-5/32" diameter, with full bar stock body
    b) be 1-1/4" long, from under head, including cam
    c) have removable standard, Yale type cam
    d) cylinders and keys must be sent to Folger Adam Security Inc.
  • Special keying requests for factory supplied key cylinders are accommodated if possible.
  • Safety knob set - Specify "SK". For safety knobs both sides, specify "Double SK"
  • Indication switches - For monitoring the position of the latchbolt and/or deadlock actuator. This feature can be used for remote door monitoring, to control alarms, indicating lights, interlocking, etc. One or two internal, as well as one external switch can be supplied, depending on circuit requirements.
    Specify switch options by letters:
    "A" Switch - An internal switch for monitoring the deadlock actuator. It indicates whether or not the latchbolt is deadlocked.
    "B" Switch - An internal switch for monitoring the knob-lockout lever. It indicates whether or not the active knobs are locked out.
    "C" Switch - A switch (for installation behind the strike plate) for monitoring the latchbolt. It indicates whether or not the latchbolt is extended into its opening in the strike plate. This switch is supplied with a 16-gauge, galvanized steel housing.

NOTE:
When door is open, the deadlock actuator and/or "C" switch can be manually depressed thereby giving a false indication that the door is locked. This can be eliminated, if desired, by installing a door position switch and wiring it together with the indication switch(es) for the lock. A "secure" signal can then be produced only after three conditions have been met:
(1) deadlock actuator is depressed;
(2) latchbolt is extended into the strike and deadlocked; and
(3) door is closed
NS400M & MCD Series 
 
Ns400.gif (13854 bytes)

 

TWO-POSITION MOTOR ACTUATED MODELS:
Lock or unlock when the motor is energized (1): by either a two or three position maintained contact switch, or three position, momentary contact switch. When unlocked by control switch, latchbolt remains retracted by motor position until control switch is set to lock. Latchbolt is held mechanically retracted until the door is opened. It will then extend automatically, if the control switch is set to the lock position. (Mechanical Latchback)

Lock or unlock when the motor is energized (2): by either a two or three position maintained contact switch, or a three position momentary contact switch. Latchbolt then remains retracted until selected to lock. Opening and closing the door has no effect on the lock. (No Latchback)

Unlocks when the motor is energized (3): by a momentary contact switch. A relock switch energizes the motor to relock once the door is open. On closure, the latchbolt deadlocks automatically. (No latchback with relock)

STANDARD COMPLIANCE:
All deadlatch models, UL1034: Burglary-Resistant Mechanisms.
All models (except two-position motor actuated), UL10B: Electrically controlled single point locks or latches, three-hour rating, A label.


STANDARD FEATURES:
  • 300 lb. Rated side load motor operation (Models NS400M, NS400MC)- Preclude jamming by applying side pressure on the door.
  • Compact size - Designed for hollow metal frames with standard 2" face.
  • Two-piece, twelve-pin plug connector - Simplifies wiring, allows pre-wiring of the lock opening.
  • Heavy duty lock mechanism - Designed to complement the high-torque motor. Corrosion resistant working parts tested over 1,000,000 cycles.
  • Stainless steel strike - Angled lip type, furnished with Torx tamper resistant screws. Requires less force to close and lock the door.
  • Mechanical latchback (Models NS400M, NS400MC) - Holds latchbolt retracted until door opens.
  • Mechanical unlocking by key - Offers manual control at the door in event of power failure, or at any other time.
  • Stainless steel latchbolt - ¾" throw, with hardened steel inserts to prevent sawing.
  • Relock switch (Model NS400MC) - Repositions motor to relock when door is opened.
  • Finish - US32D, satin stainless steel.

OPTIONAL FEATURES:
  • Indication switch- An internal switch to monitor the positions of the deadlock actuator. Signals deadlocked condition.
  • Note: When door is open, deadlock actuator may be manually depressed, thereby giving a false indication that the door is locked. This can be eliminated by installing a door position switch and wiring it in series with the indication switch in the lock. A "secure" signal can then be produced only after three conditions have been met:
    (1) deadlock actuator is depressed
    (2) deadbolt is extended and deadlocked, and
    (3) door is closed.
  • Interlocking of doors requires special wiring and/or adaptations in control consoles.
  • Builders hardware key cylinders - High security six pin tumbler cylinder may be specified. Special keying requests will be accommodated, if possible.
  • Note: Customer supplied key cylinders may be used to adapt NS400 Series locks to a specific keying system. These cylinders must have:
    a) 1-5/32" diameter, full bar stock bodies,
    b) 1-1/8" length, including cam,
    c) Standard, removable Yale-type cam.
  • Cylinders and all keys should be sent to Folger Adam Security Inc. in any case, but are required with LEK feature and cylinder extensions.
  • Local electric key (LEK) - Inmate key operates lock electrically, staff keys always operate the lock manually, and can operate it electrically. Feature is enabled or canceled from a remote control console.
  • Inmate push button - Allows operation of the lock from inside the room or cell, may be canceled from central control console. A double pole, double throw switch is available for additional functions.
  • Key cylinder extension - Required when lock is keyed on the stop side of the door frame. Five standard lengths are offered:
    Jamb size/Cylinder extension
    4-1/2"-5" 4-3/4"
    5"-6"    5-3/4"
    6"-7"    6-3/4"
    7"-8"    7-3/4"
    8"-9"    8-3/4"
  • Note: Please specify appropriate cylinder extension length when ordering. Special lengths may be provided for other jamb thickness', please contact factory for pricing and availability
800M ES or ER Gate Lock
TESTING:
The 800 Series Electric Gate locks have electrically tested for over 1,000,000 operating cylces.
STANDARD FEATURES:
  • Solenoid actuated - 120VAC, 60hz, continuous-duty type.
  • Unlocking by prison paracentric key - In case of power failure, or for local control. When unlocked by key, deadbolt remains retracted until relocked by key.
  • Deadlocks automatically - When gate is closed.
  • Adjustable mounting and locking tongue - Fits fence posts between 2-3/8" and 8-5/8" diameter; gate posts between 1-5/16" and 4-1/2" diameter.
  • Push-in type terminal strip - For easy field wiring.
  • Case and cover - 7 gauge steel
  • Corrosion resistant working working parts
  • Stainless steel deadbolt - ¾" diameter
  • Hardened-steel deadlock lever
  • Five lever tumblers - Made of spring-temper brass, activated by heavy phosphor-bronze springs.
  • One piece key cylinder - Investment cast, bronze alloy with paracentric keyway. (Paracentric, lever tumbler keys must be purchased separately.)
  • Break-off security screws - For attaching cover.
  • Finish - Galvanized, for corrosion resistance.
  • Supplied - With mounting brackets, locking tongue and mounting screws.
  • Indication Switch - A lock status switch monitors the deadbolt and its deadlocked condition.

OPTIONAL FEATURES:
  • Six lever tumblers
  • Solenoid voltage - 220VAC, 60hz

Note: When gate is open, the switch actuator for the locking tongue can be manually depressed, thereby giving a false indication that the gate is locked. This can be eliminated, if desired, by installing a gate-position indication switch and wiring it is series with the indication switch in the lock. A "secure" signal can the be produced only after three conditions have been met:
1) locking tongue switch actuator is depressed;
2) deadbolt is extended and deadlocked, and
3) gate is closed.

Note: Electrical interlocking of gates requires special wiring and/or adaptations for control consoles.