Trouble Shooting Folger Adam FA700 Strikes

Under normal usage the 700 electric strike should be cleaned and lubricated once a year to maintain its reliability. In applications with high usage or dirty conditions, more frequent service may be necessary. Lubrication points are identified in the illustration. When servicing a 700, inspect the internal parts for excess wear for breakage and lightly lubricate per the instructions. Lubricate with HPG Grease , available here.

Note: Never lubricate any strike with oil, such lubrication collects dirt and forms an abrasive and sticky compound that may affect the function of the strike.

To Inspect and Lubricate the Strike:


1. Remove the strike from the face plate, held on by two (2) 8-32 x 3/8 PHPMS.

2. Remove the front cover, held on by two (2) 4-40 x 3/16 FHMS.  Removal of the front cover should be done slowly because the locking cam spring may snap out of place.  Also, care should be taken to insure that the baffle is not lost.

3. Remove the cam spring and the baffle.

4. PULL TYPE: Loosen the lock nut holding the solenoid, then remove the solenoid and then the plunger.
PUSH TYPE: Loosen the lock nut holding the solenoid, then remove the solenoid and plunger assembly.

5. Remove the locking cam.

6. Remove the locking lever spring and locking lever.

7. Lubricate the area in the case where the locking lever and locking cam rests Note: Be careful not to get lubricant on the solenoid or switches.  Lubricate the cam pin and lever pin.

8. Check the locking angle of the keeper and locking lever for wear.  Replace the keeper and/or lever if worn.  If the keeper is disassembled for replacement or adding of a switch, lubricate the keeper.

9. Reinstall the locking lever and the locking lever spring, the spring must be held compressed into the hole in the locking lever for installation.
10. Check the solenoid, plunger and plunger guide for excess wear, dirt grime or oil, if present wipe clean.
PUSH TYPE: Remove the retaining ring for inspection of the plunger guide.  Reassemble the solenoid and plunger with a new retaining ring.
11. Pull TYPE: Lubricate the roll pin and the locking cam surfaces between the solenoid plunger (contact points of the solenoid plunger)
12. Reinstall the locking cam.  If the strike has a LCM, LBMLCM or LCMA switch make sure the roll pin on the locking cam is positioned in front of the switch actuator arm.